what does a spectrometer measure
Product Description

High resolution Spectrometer Aurora 4000 wiith the features of Small appearance, easy to carry, convenient operation, customized wavelength range and resolution and fit various applications support .The New product Aurora-IR-pro with spectrometer ftir range from 950nm to 1200nm. The optical emission spectrometer Aurora 4000 is  widely used in the fileds of biological cell analysis, chemical research,Fiber Coupled LED analysis, absorbance measurement and so on. Besides , it supports download for spectral analysis 5.0.

CNI also provides many kinds of spectrum analysis accessories, such as Raman Spectrometer,optical filter, Laser Power Meter, Laser Goggles, spectrum calibration Laser, tungsten Lamp, halogen light source, laser safety protection board, etc.

11Features

  • Up to 0.1 nm (FWHM) optical resolution
  • Convenient operation
  • Customized wavelength range and resolution
  • Fit various applications  
  • Support download for Spectral Analysis 5.0

11Applications11111111111111111111111111111

  • Laser spectral analysis
  • Fluorescence spectral analysis
  • Raman spectral analysis
  • Reflectivity/transmittance measurement
  • LED analysis
Available Model

Model             Spectral Range             
Aurora4000 General Series
GE 350-1100nm
GE 200-1100nm
GE-Raman 
New  Aurora-UV-Pro

185-240 nm

New  Aurora-IR-Pro

950-1200 nm

Aurora4000 Extemal Triggering series

(EX-TA box)

TG 350-1100nm
TG 200-1100nm

Typical Spectrometer

Model

Wavelength

1583113466 1

      Optrical resolution (nm)        
Entrance aperture (um)
 10   25   50  100 200

Aurora

4000

200-1100nm 0.75 1.09 1.83 3.45 6.61
350-1100nm 0.75 1.09 1.83 3.45 6.61
300-515nm 0.15 0.26 0.44 0.83 1.58
400-837nm 0.44 0.53 0.89 1.68 3.21
785-1100nm 0.35 0.38 0.64 1.21 2.31


Wavelength Customizable Spectrometer

Model Entrance Aperture Spectral Range Optical Resolution (nm)

Aurora

4000

10um
200-347nm 0.14
226-369nm
0.18
310-404nm 0.16
319-455nm 0.13
400-480nm 0.08
423-547nm 0.12
480-568nm 0.12
546-653nm 0.12
568-634nm 0.09
654-754nm 0.10
748-837nm 0.23
749-876nm 0.24
876-940nm 0.20
940-1100nm 0.20

Standard Specifications

Detector

Detector                    Toshiba TCD 1304DG liner CCD array                 
Wavelength range
200-1100nm
Pixels
3648 pixels
Pixel size 8*200um
Sensitivity

130 photons/ count at 400nm

60 photons/ count at 600nm


Sp
ectrometer

Dimensions (nm)                         149*105*46
Weight (g) 840
Optical resolution

<0.75nm FWHM (Depending om the grating mark density and the alit size , 

available in a varinety of options)

Signal-to-nois-ratio ~300:1
Integration time 4ms~10s
Stray light <0.05%@600nm;<0.10%@435nm

Corrected Linearity

>99.8%

Optical Bench

Design

f/4, Symmetrical crossed Czerny-Turner                    

Focal length 101.6mm input and output
Entrance aperture (um) 5, 10, 25, 50, 100 or 200
Grating

A variety of differernt grating, ultraviolet and infrared

Fiber optic connector

SMA905 to 0.22 numerical aperture single-strand fiber   

Electronics

Power consumption                         450mA@5VDC                                                                                      
Trigger mode 2 kinds
Data transter speed Full scans into memory every 4ms with USB 2.0; every 18ms with USB 1.1            
Inputs/ outputs   5 inputs and 5 outputs (opto-isolator inputs/ outputs)
Connector 30-pin connector

Applications

Raman Spectrum

What Does a Spectrometer Measure                          Spectrometer Ftir




Nd:YAG Fluorescence Spectrum


What Does a Spectrometer Measure                        Spectrometer Ftir


Fluorescence Spectrum

What Does a Spectrometer Measure                         Optical Emission Spectrometer

Certification

near infrared spectrometer

Copmpany Information 

Changchun New Industries (CNI), founded in 1996, located in Changchun, CHINA, is a manufacturer of solid-state and diode laser systems. CNI possesses accountable and dependable service as well as quality products with compact design, high reliability, good performance. The products are widely used for scientific research, equipment manufacturing, biomedical experiment, precision measurement, entertainment, radar communication, material processing, process control, online detection, investigation equipment and other fields.

Exhibitions

Home> Products> Spectrometer> Optic Fiber Spectrometer> High Resolution Optical Fiber Spectrometer
CNI LASER: Complete Solution for Laser Technology!
Tel : 86-0431-85603799
Whatsapp : +8613514405706
Address : No.888 Jinhu Road High-tech Zone, Changchun, Jilin China
Email : asia@cnilaser.com

Copyright © 2024 Changchun New Industries Optoelectronics Technology Co., Ltd. All rights reserved. Privacy Policy

Send Inquiry
*
*

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send