RPB-360 Raman Probe

Rpb-360 Raman probe

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------


Technical parameters


Designation RPB-360 Raman probe
Size 111*38*14.8mm and the top of the probe is 38mm
Material Probe material 2A12, dyed black; The top of the probe is made of stainless steel
Optical Fiber Two permanently arranged single-core optical fibers (100um excitation optical fiber, 200um standard collector optical fiber), N.A.=0.22, PVC sheath/metal sheath. Fiber length: 1m
Coupling system SMA905 connector
Raman frequency shift 456cm-1-9921cm-1
Focal length 7.5mm
Operating temperature 0-40℃

____________________________________________________________________________________________________________________________

RPB-405 Raman probe

Rpb-405 Raman probe

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------


Technical parameters


Designation RPB-405 Raman probe
Size 111*38*14.8mm and the top of the probe is 38mm
Material Probe material 2A12, dyed black; The top of the probe is made of stainless steel
Optical fiber Two permanently arranged single-core optical fibers (100um excitation optical fiber, 200um standar collector optical fiber), N.A.=0.22, PVC sheath/metal sheath. Fiber length: 1m
Coupling system SMA905 connector
Raman frequency shift 300-4700cm-1
Focal length 7.5mm
Operating temperature 0-40℃

____________________________________________________________________________________________________________________________

RPB-532 Raman probe

Rpb-532 Raman probe

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------


Technical parameters


Designation RPB-532A Raman probe RPB-532B Raman probe
Size 111*38*14.8mm and the top of the probe is 38mm
Material Probe material 2A12, dyed black; The top of the probe is made of stainless steel
Optical fiber wo permanently arranged single-core optical fibers (100um excitation optical fiber, 200um standar collector optical fiber), N.A.=0.22, PVC sheath/metal sheath. Fiber length: 1m
Coupling system SMA905 connector
Raman frequency shift 150-4500cm-1
400-4500cm-1
Focal length 7.5mm
Operating temperature 0-40℃

Raman spectra of ethanol were obtained by RPB-532

Spectra-Measured-By-RPB-532


____________________________________________________________________________________________________________________________


RPB-633 Raman probe

Rpb-633 Raman probe

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------


Technical parameters


Designation RPB-633 Raman probe
Size 111*38*14.8mm and the top of the probe is 38mm
Material Probe material 2A12, dyed black; The top of the probe is made of stainless steel
Optical fiber Two permanently arranged single-core optical fibers (100um excitation optical fiber, 200um standar collector optical fiber), N.A.=0.22, PVC sheath/metal sheath. Fiber length: 1m
Coupling system SMA905 connecto
Raman frequency shift 200-4000cm-1
Focal length 7.5mm
Operating temperature 0-40℃

Raman spectra of ethanol were obtained by PRB-633


Spectra-Measured-By-RPB-633


____________________________________________________________________________________________________________________________

RPB-785 Raman probe

Rpb-785 Raman probe

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------


Technical parameters


Designation RPB-785 Raman probe
Size 111*38*14.8mm and the top of the probe is 38mm
Material Probe material 2A12, dyed black; The top of the probe is made of stainless steel
Optical fiber Two permanently arranged single-core optical fibers (100um excitation optical fiber, 200um standar collector optical fiber), N.A.=0.22, PVC sheath/metal sheath. Fiber length: 1m
Coupling system SMA905 connecto
Raman frequency shift 175-4000cm-1
Focal length 7.5mm
Operating temperature 0-40℃


Raman spectra of ethanol were obtained by PRB-785

Spectra-Measured-By-RPB-785


____________________________________________________________________________________________________________________________

RPB-830 Raman probe

Rpb-830 Raman probe

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------


Technical parameters


Designation RPB-633 Raman probe
Size 111*38*14.8mm and the top of the probe is 38mm
Material Probe material 2A12, dyed black; The top of the probe is made of stainless steel
Optical fiber Two permanently arranged single-core optical fibers (100um excitation optical fiber, 200um standar collector optical fiber), N.A.=0.22, PVC sheath/metal sheath. Fiber length: 1m
Coupling system SMA905 connecto
Raman frequency shift 300-2048cm-1
Focal length 7.5mm
Operating temperature 0-40℃

____________________________________________________________________________________________________________________________

RPB-1064 Raman probe

RPB-1064

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------


Technical parameters


Designation RPB-1064 Raman probe
Size 111*38*14.8mm and the top of the probe is 38mm
Material Probe material 2A12, dyed black; The top of the probe is made of stainless steel
Optical fiber Two permanently arranged single-core optical fibers (100um excitation optical fiber, 200um standar collector optical fiber), N.A.=0.22, PVC sheath/metal sheath. Fiber length: 1m
Coupling system SMA905 connecto
Raman frequency shift Stokes: 390-2731cm-1 Anti-Stokes: -1127.82 ~ -348.09cm-1
Focal length 7.5mm
Operating temperature 0-40℃

Raman spectra of ethanol were obtained by PRB-1064

Spectra-Measured-By-RPB-1064

____________________________________________________________________________________________________________________________

FPB-808 Raman probe__

Rpb 360 Raman Probe

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------


Technical parameters


Designation FPB-808 Raman probe
Size 111*38*14.8mm and the top of the probe is 38mm
Material Probe material 2A12, dyed black; The top of the probe is made of stainless steel
Optical fiber Two permanently arranged single-core optical fibers (100um excitation optical fiber, 200um standar collector optical fiber), N.A.=0.22, PVC sheath/metal sheath. Fiber length: 1m
Coupling system SMA905 connecto
Raman frequency shift 365-720nm
Focal length 7.5mm
Operating temperature 0-40℃

Spectra-Measured-By-FPB-808

Spectra-Measured-By-FPB-808


____________________________________________________________________________________________________________________________

FPB-980 Raman probe

Rpb 405 Raman Probe

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------


Technical parameters


Designation FPB-980 Raman Probe
Size 111*38*14.8mm and the top of the probe is 38mm
Material Probe material 2A12, dyed black; The top of the probe is made of stainless steel
Optical fiber Two permanently arranged single-core optical fibers (100um excitation optical fiber, 200um standar collector optical fiber), N.A.=0.22, PVC sheath/metal sheath. Fiber length: 1m
Coupling system SMA905 connecto
Raman frequency shift 300-840nm
Focal length 7.5mm
Operating temperature 0-40℃


FPB-980

Spectra-Measured-By-FPB-980


____________________________________________________________________________________________________________________________


Share to:

LET'S GET IN TOUCH

CNI LASER: Complete Solution for Laser Technology!
Tel : 86-0431-85603799
Whatsapp : +8613514405706
Address : No.888 Jinhu Road High-tech Zone, Changchun, Jilin China
Email : asia@cnilaser.com

Copyright © 2024 Changchun New Industries Optoelectronics Technology Co., Ltd. All rights reserved. Privacy Policy

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send